Skip to content

[PWGLF] modified event and signal loss task #22280

[PWGLF] modified event and signal loss task

[PWGLF] modified event and signal loss task #22280

Triggered via pull request December 21, 2025 12:44
Status Failure
Total duration 14s
Artifacts

o2-linter.yml

on: pull_request_target
O2 linter
11s
O2 linter
Fit to window
Zoom out
Zoom in

Annotations

8 errors and 2 notices
O2 linter
Process completed with exit code 1.
O2 linter result
Issues have been found.
[name/configurable]: PWGLF/Tasks/Resonances/phianalysisrun3_PbPb.cxx#L132
Use lowerCamelCase for names of configurables and use the same name for the struct member as for the JSON string. (Declare the type and names on the same line.)
[name/workflow-file]: PWGLF/Tasks/Resonances/phianalysisrun3_PbPb.cxx#L1
Name of a workflow file must match the name of the main struct in it (without the PWG prefix). (Class implementation files should be in "Core" directories.)
[name/o2-task]: PWGLF/Tasks/Resonances/phianalysisrun3_PbPb.cxx#L1
Specify task name only when it cannot be derived from the struct name. Only append to the default name.
[name/o2-task]: PWGLF/Tasks/Resonances/phianalysisrun3_PbPb.cxx#L2091
Specified task name phianalysisrun3_PbPb produces an invalid device name phianalysisrun3_-pb-pb.
[pdg/database]: PWGLF/Tasks/Resonances/phianalysisrun3_PbPb.cxx#L43
Do not use TDatabasePDG directly. Use o2::constants::physics::Mass... or Service<o2::framework::O2DatabasePDG> instead.
[root/lorentz-vector]: PWGLF/Tasks/Resonances/phianalysisrun3_PbPb.cxx#L49
Do not use the TLorentzVector legacy class. Use std::array with RecoDecay methods or the ROOT::Math::LorentzVector template instead.
O2 linter
To tolerate certain issues in a directory, add a line with the test name in "o2linter_config".
O2 linter
Exceptionally, you can disable a test for a line by adding a comment with "o2-linter: disable=" followed by the name of the test and parentheses with a reason for the exception.