Notifications
You must be signed in to change notification settings - Fork 26
Open
Labels
bugSomething isn't workingSomething isn't workingcameraRelated to cameras and camera backendsRelated to cameras and camera backendsguiRelated to the GUI itself : windows and fields bugs, UI, UX, ...Related to the GUI itself : windows and fields bugs, UI, UX, ...
Milestone
Description
Hi,
I'm using an Imaging Source DMK 37BUX287 camera for recording and have set the frame rate to 100 fps, as shown in the image below:

Although the saved video file indicates a frame rate of 100 Hz, when I connect the camera's strobe output to an oscilloscope, I only measure a frequency of 60 Hz:

I've also tried adjusting the frame rate in IC Capture software, where the fps and the strobe output frequency align. So I guess there might be some issues in dlclive camera control I/O.
Thank you for your help.
Reactions are currently unavailable